Balance Community Materials test laboratory · SnapLab

Record W26DZ-2
Product Axiom MK2
Reference standard ISA 41 v3 (Highline Webbing)

Batch test record

Axiom MK2W26DZ-2

Production batch of Axiom MK2. Every figure below was measured on material drawn from this batch.

BALANCE COMMUNITY BATCH W26DZ-2 RELEASED
Batch
W26DZ-2
Product
Axiom MK2
Produced
August 2026
Status
Released
Sewing location
In-house, Colorado, USA
Destruction tests
10 in 2 configurations
Dimensional results
3 measurements
Elongation readings
3 ISA method
Laboratory
In-house SnapLab

1Product

Axiom MK2
Catalog photograph
Material
100% UHMWPE (HMPE)
Structure
Flat
Nominal width
20.0mm
Nominal weight
31g/m
Certification
None assigned

2Dimensions

Measured on this batch

ISA 41 §7

Cross-section
Weight: 32 g/m
Cross-section, drawn to scale
Dimensional results
Measurement Specimens Mean
12345
WidthM1,219.5mm19.2mm19.3mm19.8mm19.4mm19.4mm
ThicknessM1,32.5mm2.5mm2.4mm2.4mm2.5mm2.5mm
WeightM1,432g/m32g/m32g/m32g/m32g/m32g/m

3Elongation

Stretch under load

ISA 41 §9
200 mm gauge

Stretch under loadM5
Load Specimens Mean
12345
1kN ISA0%0%0%0%0%0.0%
5kN ISA1.25%1.25%1%1%1%1.1%
10kN ISA1.75%1.75%1.75%1.75%1.75%1.75%

Rows marked ISA follow the standardized ISA stretch method on a 200 mm gauge, read at the method’s own load steps; the 1 kN row is the reference reading the gauge was marked at. Measured this way, the figures are directly comparable between webbings.

The stretch sample's loops were sewn with pattern 504 (Diamond ramp for 20 mm webbings). Sewing details.

Stretch curve Not recorded
0 1 20246810120.0 % at 1 kN1.1 % at 5 kN1.75 % at 10 kN Elongation (%) Force (kN) 0 1 20246810120.0 % at 1 kN1.1 % at 5 kN1.75 % at 10 kN Elongation (%) Force (kN)

4Tensile strength

2 test setups, reported separately

ISA 41 §10 / §11
App. G

Each configuration is reported separately and never pooled with another. Specimen numbering restarts within each one.M6

4.1Summary of findings

Breaking force by test configuration

Configuration Samples Mean Std. dev. σ 3σ MBS
Blue Whale to Blue Whale Determines Batch MBS 5 45.11kN 0.72kN 42.96kN
Sewn Loop to Sewn Loop 5 47.73kN 1.64kN 42.82kN

3σ MBS is the mean breaking force less three population standard deviations, per ISA 41 Appendix G.

4.2Blue Whale to Blue Whale

Determines Batch MBS

Procedure · Blue Whale to Blue Whale

Determines the webbing's own MBS. This device, the Blue Whale, is based on the device used by the ISA for testing the strength of slackline webbings. We have created our own version that has a slightly different anchor method for the tail and modified anchor hole to fit our test machine. The device has an 80mm drum that the webbing wraps around and is ultimately anchored at the back of the device with a short sewn loop.

The Blue Whale is anchored to the test bed directly, with each end in opposite orientations. The webbing wraps around each side in opposite ways to allow for even stretching across the width and thickness of the webbing to prevent uneven loading caused by bent samples. Since the webbing is ultimately anchored with a short sewn loop, the entire sample is able to be tested as there are no tails exiting the sample space.

  • Sample Length - 2.0 m (6.5 ft)

  • Pull Rate - ~350 mm per minute

Sewing pattern Pattern 504

Loop pattern behind these specimens

Pattern 504

Sewn Loop

Sewn loop, pattern 504, Axiom MK2

3D preview Click to interact Loading 3D… Drag to tumble · scroll to zoom · double-click to reset

Pattern dimensions
160 × 16 mm (L × W) (6.3 × 0.6 in)
Opening size
140 mm (5.5 in)
Webbing fold
305 mm (12.0 in)
Sleeve length
200 mm (7.9 in)
Bobbin thread
Amann Xtreme Tech with Dyneema · 220-tex · Yellow
Needle thread
Amann Xtreme Tech with Dyneema · 220-tex · Red
Stitches
200

Needle threadBobbin threadSleeveModelled to scale.

Written specification

Pattern
504end loop, folded
Fits webbing
20 mmnominal width
Webbing
20.0 × 2.5 mm nominal W × T
Stitch density
1.3 per mmover the pattern length
Opening range
25 to 300 mm settable when the end is built
Drawing source
Machine pattern file stitch run plotted to scale
Specimens
5
Mean force
45.11kN
Std. deviation σ
0.72kN
3σ MBS
42.96kN
Specimen results
Specimen Breaking force
Sample 1 45.89kN
Sample 2 44.62kN
Sample 3 44.02kN
Sample 4 45.19kN
Sample 5 45.84kN
Force in kN against time in seconds, 5 specimens overlaid. The dashed rule is the mean and the accented rule the 3σ MBS; a dot marks each peak, and the fall after it is the break. Every breaking force is in the table beside the plot. Hover or focus a specimen row to trace it here. Press the plot to read values off it, zoom and hide series; Escape gives the picture back.

4.3Sewn Loop to Sewn Loop

Procedure · Sewn Loop to Sewn Loop

Determines strength retention in a sewn loop. The particular pattern used for sewing is indicated on each test.

Each sewn loop is done in an opposite direction in order to take out the possibility of failure by uneven loading across the width and thickness of the webbing. Each sewn loop is directly attached to the clevis pins on our test machine, with a diameter of pin diameter of 19mm.

These tests are often used as our elongation tests as well, since they experience the least change in length within the anchoring method.

  • Webbing starting length - 1.5 m (5 ft)

  • Pull Rate - ~350 mm per minute

Sewing pattern Pattern 504

Loop pattern behind these specimens

Pattern 504

Sewn Loop

Sewn loop, pattern 504, Axiom MK2

3D preview Click to interact Loading 3D… Drag to tumble · scroll to zoom · double-click to reset

Pattern dimensions
160 × 16 mm (L × W) (6.3 × 0.6 in)
Opening size
140 mm (5.5 in)
Webbing fold
305 mm (12.0 in)
Sleeve length
200 mm (7.9 in)
Bobbin thread
Amann Xtreme Tech with Dyneema · 220-tex · Yellow
Needle thread
Amann Xtreme Tech with Dyneema · 220-tex · Red
Stitches
200

Needle threadBobbin threadSleeveModelled to scale.

Written specification

Pattern
504end loop, folded
Fits webbing
20 mmnominal width
Webbing
20.0 × 2.5 mm nominal W × T
Stitch density
1.3 per mmover the pattern length
Opening range
25 to 300 mm settable when the end is built
Drawing source
Machine pattern file stitch run plotted to scale
Specimens
5
Mean force
47.73kN
Std. deviation σ
1.64kN
3σ MBS
42.82kN
Specimen results
Specimen Breaking force
Sample 1 45.12kN
Sample 2 47.69kN
Sample 3 49.41kN
Sample 4 46.93kN
Sample 5 49.5kN
Force in kN against time in seconds, 5 specimens overlaid. The dashed rule is the mean and the accented rule the 3σ MBS; a dot marks each peak, and the fall after it is the break. Every breaking force is in the table beside the plot. Hover or focus a specimen row to trace it here. Press the plot to read values off it, zoom and hide series; Escape gives the picture back.

Other batches of Axiom MK2

Tested and reported by

Balance Community, materials test laboratory

SnapLab break-test platform

Record control

Record W26DZ-2

Produced August 2026

Status Released

Reference standard ISA 41 v3

Scope of this record

Covers only material produced in batch W26DZ-2. Figures are not transferable to other production runs of the same product.

This is an in-house test record, not a third-party certification. Testing was performed by Balance Community on its own equipment, following the procedures of ISA 41 (Highline Webbing, v3) as referenced against each section. The 3σ MBS values published here use the population standard deviation (divisor N), per Appendix G.

← Back to Axiom MK2