Balance Community Materials test laboratory · SnapLab
Record Sample 1
Product Axiom MK2
Batch W26DZ-2
Breaking force
45.12kN
Force–time trace
Test details
- Tested
- Oct 15, 2026 · 14:45
- Duration
- 167.4s
- Scan rate
- 500Hz
- Sample
- 1
- Study
- Batch Report - Axiom MK2 - W26DZ-2
- Test machine
- SnapLab break-test bench
- DAQ device
- LabJack T7
- Beam location
- No. 2 — Second position
Instrumentation
| Channel | Sensor | Type | Units | Calibrated |
|---|---|---|---|---|
| AIN2 Main | Main Force Sensor | force | kN | Not recorded |
Method
Configuration Sewn Loop to Sewn Loop
Sewing pattern Diamond ramp for 20 mm webbings Pattern 504
Determines strength retention in a sewn loop. The particular pattern used for sewing is indicated on each test.
Each sewn loop is done in an opposite direction in order to take out the possibility of failure by uneven loading across the width and thickness of the webbing. Each sewn loop is directly attached to the clevis pins on our test machine, with a diameter of pin diameter of 19mm.
These tests are often used as our elongation tests as well, since they experience the least change in length within the anchoring method.
Webbing starting length - 1.5 m (5 ft)
Pull Rate - ~350 mm per minute