Balance Community Materials test laboratory · SnapLab

Record Width
Product Paradigm MK2
Batch W26AM

Dimension measurement

Width

Paradigm MK2Batch W26AM

Measured

24.75mm

Mean of 6 samples (24.5–24.9 mm)

Test details

Study
Batch Report - Paradigm MK2 - W26AM
Test machine
SnapLab break-test bench
DAQ device
LabJack T7
Fixed grip
10kg
Moving grip
10kg

Instrumentation

Recorded channels
Channel Sensor Type Units Calibrated
MANUAL_0 Main Calipers dimensions mm Apr 15, 2026

Specimen readings

The figure above is the mean of 6 specimens, measured in this order:

Individual readings
Specimen Reading
1 24.7mm
2 24.5mm
3 24.9mm
4 24.9mm
5 24.8mm
6 24.7mm

Method

Configuration Webbing Width

Measured following the ISA 41 dimensions procedure (§7): a test sample at least 2500 mm long is loaded, without shock, with a 10 kg (±0.1 kg) mass and the load is retained for at least 60 seconds before measuring.

With the load still applied, the width is measured in mm to a precision of 0.1 mm.