Balance Community Materials test laboratory · SnapLab
Record Width
Product Silk 99
Batch W25YZ
Measured
18.85mm
Mean of 6 samples (18.1–19.1 mm)
Test details
- Study
- Batch Report - Silk 99 - W25YZ
- Test machine
- SnapLab break-test bench
- DAQ device
- LabJack T7
- Fixed grip
- 10kg
- Moving grip
- 10kg
Instrumentation
| Channel | Sensor | Type | Units | Calibrated |
|---|---|---|---|---|
| MANUAL_0 Main | Calipers | dimensions | mm | Apr 15, 2026 |
Specimen readings
The figure above is the mean of 6 specimens, measured in this order:
| Specimen | Reading |
|---|---|
| 1 | 18.1mm |
| 2 | 18.7mm |
| 3 | 19.1mm |
| 4 | 19.1mm |
| 5 | 19.0mm |
| 6 | 19.1mm |
Method
Configuration Webbing Width
Measured following the ISA 41 dimensions procedure (§7): a test sample at least 2500 mm long is loaded, without shock, with a 10 kg (±0.1 kg) mass and the load is retained for at least 60 seconds before measuring.
With the load still applied, the width is measured in mm to a precision of 0.1 mm.