Balance Community Materials test laboratory · SnapLab
Record Sample 1
Product Mantra MK4
Batch W25AI
Breaking force
39.32kN
Force–time trace
Test details
- Tested
- Jul 29, 2026 · 15:42
- Duration
- 65.5s
- Scan rate
- 500.0Hz
- Sample
- 1
- Study
- Batch Report - Mantra MK4 - W25AI
- Test machine
- SnapLab break-test bench
- DAQ device
- LabJack T7
- Beam location
- No. 2 — Second position
- Fixed grip
- AWL6
- Moving grip
- AWL6
Instrumentation
| Channel | Sensor | Type | Units | Calibrated |
|---|---|---|---|---|
| AIN2 Main | Main Force Sensor | force | kN | Not recorded |
Method
Configuration Alpine WebLock 6 to Alpine WebLock 6
Determines strength retention in the 6-series Alpine Weblock.
Each AWL6 is anchored to the test bed with a Van Beast Shackle (usually 1/2" or 5/8", depending on the webbing strength). The webbing sample is installed in each weblock in the same orientation on both ends with a minimal tail (75 - 150 mm (3 - 6 inches)). The sample is then pulled to failure.
Sample Length - 1.5 m (5 ft)
Pull Rate - ~350 mm per minute