Balance Community Materials test laboratory · SnapLab

Record Thickness
Product Mantra MK4
Batch W25AI

Dimension measurement

Thickness

Mantra MK4Batch W25AI

Measured

3.34mm

Mean of 6 samples (3.32–3.36 mm)

Test details

Study
Batch Report - Mantra MK4 - W25AI
Test machine
SnapLab break-test bench
DAQ device
LabJack T7
Fixed grip
10kg
Moving grip
10kg

Instrumentation

Recorded channels
Channel Sensor Type Units Calibrated
MANUAL_0 Main Calipers dimensions mm Apr 15, 2026

Specimen readings

The figure above is the mean of 6 specimens, measured in this order:

Individual readings
Specimen Reading
1 3.34mm
2 3.36mm
3 3.34mm
4 3.32mm
5 3.33mm
6 3.34mm

Method

Configuration Webbing Thickness

Measured following the ISA 41 dimensions procedure (§7): a test sample at least 2500 mm long is loaded, without shock, with a 10 kg (±0.1 kg) mass and the load is retained for at least 60 seconds before measuring.

With the load still applied, the thickness is measured in mm to a precision of 0.1 mm.

Part of batch W25AI →