Balance Community Materials test laboratory · SnapLab

Record Sample 1
Product Secondaire MK2
Batch W26AC

Tensile test

Sample 1

Secondaire MK2Batch W26ACJuly 17, 2026

Breaking force

22.48kN

Force–time trace

The capture from the rig’s force channel, plotted against elapsed time.

Test details

Tested
Jul 17, 2026 · 16:13
Duration
48.7s
Scan rate
500.0Hz
Sample
1
Study
Batch Report - Secondaire MK2 - W26AC
Test machine
SnapLab break-test bench
DAQ device
LabJack T7
Beam location
No. 2 — Second position
Fixed grip
MightyLock
Moving grip
MightyLock

Instrumentation

Recorded channels
Channel Sensor Type Units Calibrated
AIN2 Main Main Force Sensor force kN Not recorded

Method

Secondaire MK2 in the MightyLock to MightyLock break-test rig, line drawing

Drag to rotate · scroll or pinch to zoom · right-drag or two-finger drag to pan

Test setup: MightyLock to MightyLock

Configuration MightyLock to MightyLock

Determines strength retention in the MightyLock line-locker ring.

We have a Mightylock installation at both ends of the webbing. The webbing is wrapped around the MightyLock in the Right-Side-Up configuration and anchored to either a 5/8" Van Beast Shackle (if it's a 25mm/1-inch webbing) or a 1/2" Van Beast Shackle (if it's a 19-20mm webbing). The tails are kept to a minimum on both ends (75 - 150mm (3 - 6 inches)).

  • Sample Length - 1.5 m (5 ft)

  • Pull Rate - ~350 mm per minute

Part of batch W26AC →